Reasons and Solutions for Servo Drive Reporting Fault Code FU101
Fault Code: FU101
Fault Description: Abnormal Internal Parameters of Servo Drive
Possible Causes and Solutions:
1. Instantaneous drop in control power supply voltage:
(1) Measure the input voltage on the non-drive side of the control cable during operation to ensure compliance with specifications (e.g., 220V drive: RMS 220V-240V, allowable deviation: -10% to +10% [198V-264V]).
(2) Increase power supply capacity or replace with a higher-capacity power supply.
(3) Restore system parameters to initialization (set P02-31=1), then rewrite parameters.
2. Power interruption during parameter storage:
(1) Confirm whether a momentary power outage occurred during the parameter saving process.
(2) Cycle power, restore system parameters to initialization (P02-31=1), and rewrite parameters.
3. Excessive parameter write operations within a limited time:
(1) Check if the host device frequently modifies parameters.
(2) Change the parameter writing method and rewrite parameters.
(3) If the fault persists, replace the servo drive.
4. Software update:
(1) Confirm if the software was recently updated.
(2) Reconfigure the drive model and motor model, then restore system parameters to initialization (P02-31=1).
5. Servo drive hardware failure:
If the fault persists after multiple power cycles and restoring factory parameters, replace the servo drive.
Note: This fault typically involves parameter corruption due to power instability, excessive writes, or software conflicts. Always ensure stable power and follow parameter modification guidelines.